A ruggedized, immersion-cooled AI compute platform integrated inside a hardened 10-foot ISO container. Data center-class GPU compute, enterprise storage, a full Cisco fabric, and private 5G, powered by hydrogen and operational within 72 hours. Anywhere the cloud is too far, too slow, or too risky, Atlas™ brings the data center to the workload.
Atlas in a hardened 10′ x 8′ x 8.5′ ISO container: flush roof and side radiators joined by a manifold, dual equipment doors with a hydrogen vent, ISO corner castings, and an integrated private 5G mast.
| Form Factor | Hardened 10-foot ISO shipping container, approximately 3 m x 3 m x 2.4 m |
| Transport | C-130 aircraft, CH-47 helicopter, standard flatbed truck, ISO container ship |
| Time to Operational | 72 hours from arrival, not weeks |
| Operating Environment | -40°C to +50°C ambient, 0 to 100 percent humidity, up to 15,000 ft altitude |
| Primary Power | Hydrogen PEM fuel cell, 10 kW scalable to 50 kW, NATO NSPA qualified |
| Off-Grid Runtime | Multi-day continuous operation on internal hydrogen storage, extendable with refueling or an external H2 skid |
| Alternate Power | Diesel generator, shore power, utility tie-in, with automatic source transfer |
| Cooling | Single-phase dielectric immersion; full submersion of compute and production networking |
| Connectivity | Integrated private 5G (CBRS band, 1 to 5 km range, 1,000+ devices), Wi-Fi 6E, wired WAN, optional satellite uplink |
| Acoustic Signature | Near-silent (no server fans); reduced visual and thermal signature in tactical use |
Every Atlas configuration shares a common platform: Cisco networking, VAST Data storage, private 5G, hydrogen fuel cell, and full immersion cooling. Choose the GPU tier that fits the mission.
All configurations: 300 TB–2.4 PB VAST Data AI OS storage • Cisco enterprise networking • Private 5G AI-RAN • Hydrogen fuel cell • Full immersion cooling • 10’ ISO container. Off-grid runtime on internal H2 storage at sustained load; extendable with refueling or an external skid.
NVIDIA Blackwell-class accelerators with a documented upgrade path to B300 and Rubin generations. DGX Spark nodes handle AI-RAN baseband and edge inference on enterprise server platforms.
VAST Data AI OS with simultaneous NFS, SMB, and S3 presentation. Inline AES-256 encryption, dedup, and compression. 300 TB to 2.4 PB usable per unit, scaling independently of GPU tier.
Cisco Nexus data center fabric with VXLAN/EVPN multi-tenant segmentation, MACsec on every internal link, Firepower NGFW, and a dry out-of-band management path for remote serviceability.
O-RAN compliant radios in CBRS band with GPU-accelerated NVIDIA Aerial baseband. SIM-based authentication, per-mission network slicing, and 1,000+ concurrent devices across a 1 to 5 km radius.
Single-phase dielectric immersion with all compute and production networking fully submerged. No fans, no particulate intrusion, continuous duty from -40°C to +50°C ambient.
Hydrogen PEM fuel cell primary with independent management-plane backup, plus diesel, utility, and shore power alternates behind automatic source transfer and UPS ride-through.
Workloads built for the cloud run on Atlas without rewrite.
| Layer | Components |
|---|---|
| Orchestration | Kubernetes (RKE2 or OpenShift), NVIDIA GPU Operator, Istio service mesh |
| AI & ML | NVIDIA AI Enterprise, PyTorch, TensorRT, Triton Inference Server, RAPIDS, NVIDIA NIM microservices |
| Data | Apache Kafka, Redis, PostgreSQL, MinIO (S3-compatible) |
| Storage Services | VAST Data AI OS, snapshot and replication |
| Management | Cisco Intersight (local appliance for disconnected mode), Prometheus, Grafana, NVIDIA DCGM |
| Security | MACsec on fabric, IPsec or TLS on WAN, LUKS volume encryption, HSM-backed key management, STIG-hardened OS |
| Standard | Applicability |
|---|---|
| MIL-STD-810H | Environmental qualification: temperature, humidity, shock, vibration, altitude, dust, rain |
| MIL-STD-461G | EMI/EMC and EMP shielding |
| DoD STIG & RMF | Security hardening and Authority to Operate pathway |
| FIPS 140-3 | Cryptographic module validation for storage and key management |
| NIST 800-53 / 800-171 | Federal control mapping and CUI handling |
| HIPAA Security Rule | Safeguards for ePHI in clinical deployments |
| NERC CIP | Critical infrastructure protection for electric utilities |
| IEC 62443 / API 1164 | Industrial control system and pipeline SCADA security |
| O-RAN / IEEE 1588 | 5G radio access compliance and precision fronthaul timing |
| NATO NSPA | Fuel cell qualification for allied logistics interoperability |
Self-contained deployable units in three GPU tiers, from multi-tenant inference and digital twin to foundation model training.
Fixed-site variant on Cisco UCS, VAST Data, and IGEL with two-site data mobility and a Blackwell AI expansion path, for operators with existing data center space.
Two to N units federated over MACsec-encrypted dark fiber or microwave, presenting as one logical fabric with per-site data residency.
Turnkey delivery with annual support: monitoring, updates, and AI model lifecycle management for customers without on-site infrastructure teams.